Test Zone Verification Procedures in a Random-LOS Measurement Setup
Paper i proceeding, 2019

© 2019 European Association on Antennas and Propagation. In this paper we analyze three different verification procedures of the test zone in the Random Line-of-Sight measurement setup. The goal is to find a way to reduce the number of samples needed to estimate the standard deviation and the mean value within a circular test zone. It was found that more than 50 samples are needed to get reliable performance with the verification procedure using two orthogonal lines. However all three investigated methods work well, but the two other methods need more than 100 samples. This means that the samples can be taken within the test zone along two orthogonal lines, in a spiral shape, as well as a combination of these two methods, depending on the user's preference.

vehicular

anechoic chamber

RLOS.

Random Line-Of-Sight

quiet zone

antenna

Författare

Madeleine Schilliger Kildal

Chalmers, Elektroteknik, Kommunikation, Antenner och Optiska Nätverk

Aidin Razavi

Ericsson AB

Jan Carlsson

Chalmers, Elektroteknik, Kommunikation, Antenner och Optiska Nätverk

Andres Alayon Glazunov

Chalmers, Elektroteknik, Kommunikation, Antenner och Optiska Nätverk

13th European Conference on Antennas and Propagation, EuCAP 2019

8740253

13th European Conference on Antennas and Propagation, EuCAP 2019
Krakow, Poland,

Ämneskategorier

Geoteknik

Analytisk kemi

Sannolikhetsteori och statistik

Mer information

Senast uppdaterat

2024-01-03