Influence of Different Sensor Configurations on the Turbulent Quantities in a Complex Three-Dimensional Flow Field
Paper in proceeding, 1993

Measurements of the Reynolds stress tensor have been carried out in a complex three-dimensional boundary layer using different techniques. Single-, cross- and three-hot-wire probes were employed together with a silicon based double chip sensor. All measurements were performed at a Reynolds number of 1.2 x ___ per meter. The turbulent stresses were determined at a reference position in a two-dimensional part of the flow field and at three locations with different strength of the three-dimensionality. A good agreement was found in the turbulent quantities measured with the different methods, however, the influence of prong interference, measuring volumes and velocity gradients were noted.

Author

Lennart Löfdahl

Chalmers, Department of Thermo and Fluid Dynamics

T.V Troung

Bert Johansson

Chalmers, Department of Thermo and Fluid Dynamics

Julius Bruns

Carl-Olof Olsson

Chalmers, Department of Thermo and Fluid Dynamics

ASME-Fluid Engineering Conference, Washington DC

Subject Categories

Fluid Mechanics and Acoustics

More information

Created

10/8/2017