The aim of this study was to compare single- and twin-shaft oxy-fuel gas turbines in a semi-closed oxy-fuel combustion combined cycle (SCOC-CC). This paper discussed the turbomachinery preliminary mean-line design of oxy-fuel compressor and turbine. The conceptual turbine design was performed using the axial through-flow code LUAX-T, developed at Lund University. A tool for conceptual design of axial compressors developed at Chalmers University was used for the design of the compressor. The modeled SCOC-CC gave a net electrical efficiency of 46% and a net power of 106 MW. The production of 95% pure oxygen and the compression of CO2 reduced the gross efficiency of the SCOC-CC by 10 and 2 percentage points, respectively. The designed oxy-fuel gas turbine had a power of 86 MW. The rotational speed of the single- shaft gas turbine was set to 5200 rpm. The designed turbine had four stages, while the compressor had 18 stages. The turbine exit Mach number was calculated to be 0.6 and the calculated value of AN2 was 40x10^6 rpm^2m^2. The total calculated cooling mass flow was 25% of the compressor mass flow, or 47 kg/s. The relative tip Mach number of the compressor at the first rotor stage was 1.15. The rotational speed of the twin-shaft gas generator was set to 7200 rpm, while that of the power turbine was set to 4500 rpm. Twin-shaft turbine designed with five turbine stages to maintain the exit Mach number around 0.5. The twin-shaft turbine required a lower exit Mach number to maintain reasonable diffuser performance. The compressor turbine was designed with two stages while the power turbine had three stages. The study showed that a four-stage twin-shaft turbine produced a high exit Mach number. The calculated value of AN2 was 38x10^6 rpm^2m^2. The total calculated cooling mass flow was 23% of the compressor mass flow, or 44 kg/s. The compressor was designed with 14 stages. The preliminary design parameters of the turbine and compressor were within established industrial ranges. From the results of this study it was concluded that both single- and twin-shaft oxy-fuel gas turbines have advantages. The choice of a twin-shaft gas turbine can be motivated by the smaller compressor size and the advantage of greater flexibility in operation, mainly in off-design mode. However, the advantages of a twin-shaft design must be weighed against the inherent simplicity and low cost of the simple single-shaft design.

twin-shaft gas turbine

CO2

Oxy fuel

SCOC-CC

mid-sized dual pressure combined cycle

single-shaft gas turbine

Author

Majed Sammak

Lund University

Magnus Genrup

Lund University

Egill Maron Thorbergsson

Chalmers, Applied Mechanics, Fluid Dynamics

Tomas Grönstedt

Chalmers, Applied Mechanics, Fluid Dynamics

Proceedings of ASME Turbo Expo 2012: Power for Land, Sea and Air. June 11-15, 2012, Copenhagen, Denmark

Vol. 3 289-297
978-079184469-4 (ISBN)

Subject Categories

Energy Engineering

Fluid Mechanics and Acoustics

Areas of Advance

Energy

DOI

10.1115/GT2012-69470

ISBN

978-079184469-4

More information

Latest update

3/2/2018 9