Determination of Stresses and Retained Austenite in Carbon Steels by X-rays – A Round Robin Study
Journal article, 2011
Residual stresses and retained austenite are two
important process-related parameters which need to be
controlled and monitored carefully during production and
heat treatment of products. X-ray diffraction techniques are normally used in this context, and the purpose of the
present study was to investigate the reproducibility and
accuracy of these methods for medium and high carbon
steels. The work was carried out as a round robin study
including nine different laboratories in Sweden and Finland. Stress measurements were carried out on three
specimens etched to three different depths, 0 μm, 230 μm
and 515 μm. Retained austenite measurements were carried
out on three specimens containing approximately 11, 17
and 30 vol.-% of this phase. The stress measurements
showed good reproducibility with standard deviations of
typically 4% on flat and smooth surfaces and not more than
about 8% on etched surfaces. Estimations revealed that
specimen misalignment and improper X-ray spot location
were the main sources behind the variation in the stress
recordings. The determination of retained austenite showed
a standard deviation of typically 15% between the different
contributors. However, by using identical evaluation methods for all raw data, the data spread could be narrowed by a factor of 3 to 4 despite the fact that different experimental settings were used in the individual laboratories.