Vacuum insulation panels (VIP) in refrigerator room, freezing room & fridge
Other conference contribution, 2013
The present contribution deals with the evolution of the internal pressure of VIPs subjected to low and freezing temperature for a period of 5 years confirming the prediction made earlier on its linear increase 0.6 mbar/year in the refrigerator room and 0.10 to 0.26 mbar/year in freezer room depending on the VIP type.
This is a clear indication that the aging process decelerates compared to the standard test condition of VIP due to the low temperature condition.
Further, a refrigerator with different VIP configuration was analysed with respect to their energy performance by means of thermal bridge analysis and possibilities to reduce them.
aging
pressure increase
floor insulation
low and freezing temperature
vacuum insulation panel
Author
Samuel Brunner
Swiss Federal Laboratories for Materials Science and Technology (Empa)
Karim Ghazi Wakili
Swiss Federal Laboratories for Materials Science and Technology (Empa)
Pär Johansson
Chalmers, Civil and Environmental Engineering, Building Technology
Dübendorf, Switzerland,
Areas of Advance
Building Futures (2010-2018)
Energy
Subject Categories
Building Technologies