Fatigue crack growth testing using varying R-ratios
Paper in proceeding, 2010

A method to generate high temperature fatigue crack growth data for multiple R-ratios during a single or only a few tests for surface crack specimens was developed. Two tests were performed; one with 0≤R≤0.8 and one with -1≤R≤0. The crack growth was monitored using the potential drop method. It was shown that the results from tests with varying R-ratio gave very similar results to test with constant R. Fatigue crack growth predictions with data from varying R-test were generally slightly more conservative compared to predictions using data obtained from conventional testing. © 2010 Published by Elsevier Ltd.

Fatigue crack growth

R-ratio

Experimental techniques

Author

Magnus Hörnqvist Colliander

T. Hansson

O. Clevfors

Procedia Engineering

1877-7058 (ISSN)

Vol. 2 1 155-161

Subject Categories

Mechanical Engineering

Materials Engineering

DOI

10.1016/j.proeng.2010.03.017