Fast room temperature THz bolometers
Paper in proceeding, 2013

A responsivity of >100 V/W was measured at room temperature for nano scale bolometers integrated with planar spiral antennas covering a frequency range from 100 GHz to 3 THz. Currently a NEP of about 200 pW/Hz^0.5 was experimentally obtained.

YBCO

YBaCuO

responsivity

THz antenna

nanobolometer

spiral antenna

terahertz detector

bolometer

Author

Stella Bevilacqua

Chalmers, Microtechnology and Nanoscience (MC2), Terahertz and Millimetre Wave Laboratory

Serguei Cherednichenko

Chalmers, Microtechnology and Nanoscience (MC2), Terahertz and Millimetre Wave Laboratory

International Conference on Infrared, Millimeter, and Terahertz Waves, IRMMW-THz

21622027 (ISSN) 21622035 (eISSN)

1-2
978-1-4673-4717-4 (ISBN)

Areas of Advance

Information and Communication Technology

Nanoscience and Nanotechnology

Subject Categories

Electrical Engineering, Electronic Engineering, Information Engineering

Nano Technology

Condensed Matter Physics

Infrastructure

Nanofabrication Laboratory

DOI

10.1109/IRMMW-THz.2013.6665544

ISBN

978-1-4673-4717-4

More information

Latest update

10/5/2023