Use of a conductivity heat-flow meter in fluidised-bed boilers
Journal article, 1989

The usefulness of a conductivity type of heat-flow meter for measurements in fluidised-bed boilers is investigated. The design and the calibration of the meter are described. Results from measurements of the local heat tranfer at the walls of fluidised-bed boilers are presented. An error analysis shows that the accuracy of the heat-flow meter is +-9%.

heat-flow meter

calibration

design

heat transfer

fluidized bed

Author

Bengt-Åke Andersson

Department of Energy Conversion

Filip Johnsson

Department of Energy Conversion

Bo G Leckner

Department of Energy Conversion

Transactions of the Institute of Measurement and Control

0142-3312 (ISSN) 1477-0369 (eISSN)

Vol. 11 2 108-112

Subject Categories

Energy Engineering

Areas of Advance

Energy

Infrastructure

Chalmers Power Central

DOI

10.1177/014233128901100207

More information