Comparison of Interior, V-Shaped, Surface Mounted Permanent Magnet and Permanent Magnet Assisted Synchronous Reluctance Generators Used as a Wave Energy Converter Generator
Paper in proceedings, 2018

In this work, interior mounted, v-shaped, surface mounted permanent magnet generators and a permanent magnet assisted synchronous reluctance generator are used as wave energy converter generators and are compared, both from performance and economical perspectives. The materials and material volumes are kept constant, as well as the control strategy. The torque-speed performances, power losses and the efficiencies are compared. The economical comparison is based on a Life Cycle Cost analysis. The favorable option regarding the performance and the life cycle cost is presented

Author

Pinar Tokat

Chalmers, Electrical Engineering, Electric Power Engineering

Torbjörn Thiringer

Chalmers, Electrical Engineering

2018 XIII International Conference on Electrical Machines (ICEM)
Alexandroupoli, Greece,

Areas of Advance

Energy

Subject Categories

Other Environmental Engineering

Energy Systems

Other Electrical Engineering, Electronic Engineering, Information Engineering

DOI

10.1109/ICELMACH.2018.8506927

ISBN

9781538624777

More information