Estimation of the winding losses of Medium Frequency Transformers with Litz wire using an equivalent permeability and conductivity method
Paper in proceeding, 2020

To achieve the highest efficiency of a Dual Active Bridge converter, it is crucial to accurately calculate the winding losses of the Medium Frequency Transformer (MFT) situated inside it. In this article, an effective numerical method for calculation of the copper losses in MFTs with rectangular-shaped windings made up of Litz wire, is utilized and practically verified.

Author

Mohammad Kharezy

Chalmers, Electrical Engineering, Electric Power Engineering

Morteza Eslamian

University of Zanjan

Torbjörn Thiringer

Chalmers, Electrical Engineering, Electric Power Engineering

2020 22nd European Conference on Power Electronics and Applications, EPE 2020 ECCE Europe


9789075815368 (ISBN)

2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe)
Lyon, France,

Driving Forces

Sustainable development

Innovation and entrepreneurship

Areas of Advance

Energy

Subject Categories

Electrical Engineering, Electronic Engineering, Information Engineering

DOI

10.23919/EPE20ECCEEurope43536.2020.9215900

More information

Latest update

4/21/2023