This paper will present a comparison between measured and CFD simulated fan performance characteristics of three different types of heavy duty truck fans. The test bench incorporates a fan, fan ring, shroud and 3D engine blockage. The latter creates a severe constraint to the use of simplified 3D CFD fan models (MRF-model). The results illustrates that the MRF methodology is consistent with test data for axial flow conditions up to fan transition, i.e. this methodology could be used for applications with a correctly installed axial fan. However after fan transition the methodology is not consistent any more.

Author

Peter Gullberg

Chalmers, Applied Mechanics, Vehicle Engineering and Autonomous Systems

Lennart Löfdahl

Chalmers, Applied Mechanics, Vehicle Engineering and Autonomous Systems

Institution of Mechanical Engineers - VTMS 10, Vehicle Thermal Management Systems Conference and Exhibition

423-433

Areas of Advance

Transport

Energy

Subject Categories

Vehicle Engineering

Fluid Mechanics and Acoustics