Measurements and simulations of corona currents due to triangular voltages in large scale coaxial geometry
Paper in proceeding, 2012

Corona currents in air measured in a large scale coaxial geometry (d_outer = 1 m, d_inner = 0.26 mm), under both DC and AC voltages of a triangular shape with frequencies in the range (1 – 50) Hz are analyzed. A computational model describing dynamics of positive and negative ionic charges is employed to examine the results of the measurements. The performed simulations show a good overall agreement with the experimental data.

drift-diffusion model

corona discharge

triangular voltage

ionic charges

Author

Joachim Schiessling

ABB

Olof Hjortstam

ABB

Uno Gäfvert

ABB

Markus Saltzer

ABB

Yuriy Serdyuk

Chalmers, Materials and Manufacturing Technology, High Voltage Engineering

Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP

00849162 (ISSN)

Vol. 1 357-360
978-1-4673-1250-9 (ISBN)

Areas of Advance

Energy

Subject Categories

Other Electrical Engineering, Electronic Engineering, Information Engineering

DOI

10.1109/CEIDP.2012.6378794

ISBN

978-1-4673-1250-9

More information

Latest update

10/5/2023