RBS channeling measurement of damage annealing in InAs/AlSb HEMT structures
Journal article, 2014

Electrical isolation of InAs/AlSb high electron mobility transistors has been achieved by the ion implantation isolation technique. The multilayered structures are grown by molecular beam epitaxy on GaAs substrates. The optimal isolation is provided by damaging patterned areas by 100 keV Ar ions implanted at room temperature using fluence of 2 x 10(15) cm(-2), and then annealing the samples in 365 degrees C for 30 min. The damage build-up and annealing is studied by channeling Rutherford backscattering spectrometry (RBS) and compared to sheet resistance measurements. Only a low level of damage annealing can be seen in RBS for the post-implant annealed samples, but for Ar fluence higher than 2 x 10(14) cm(-2), a strong electrical resistivity increase can still be achieved.

Author

A. Hallen

Royal Institute of Technology (KTH)

Giuseppe Moschetti

Chalmers, Microtechnology and Nanoscience (MC2), Microwave Electronics

Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

0168-583X (ISSN)

Vol. 332 172-175

Subject Categories

Physical Sciences

DOI

10.1016/j.nimb.2014.02.055

More information

Latest update

2/26/2018