Effects of TiO2-Coated Stainless Steel Orthodontic Wires on Streptococcus mutans Bacteria: A Clinical Study
Journal article, 2020

Introduction: The aim of this study was to clinically evaluate Streptococcus mutans adhesion on titanium dioxide-coated stainless steel orthodontic wires to decrease white-spot formation. Methods: In this study, four groups of 17 patients each (n=68) aged 12-25 years participated. A titanium dioxide coating layer was deposited on 0.4572 mm stainless steel orthodontic wires using physical vapor deposition. The coated wires were randomly assigned to one jaw, and the opposite jaw received an uncoated wire as control. Patients were divided into groups according to the duration that wires were in their mouths: A) 1 week, B) 2 weeks, C) 3 weeks, and D) 4 weeks. Block randomization was used to assign patients to each group. At the end of the experiment, 20 mm of each wire (canine-to-canine area) was cut and cultured in S. mutans-specific medium. The culture plates were placed in an incubator containing 5% CO2 for 72 hours at 37 degrees C, and then colonies were counted. MTT was used to test the biocompatibility of the coated and uncoated wires. To evaluate the stability of the coated titanium dioxide layer on the wires, titanium concentration on the saliva was determined using inductively coupled plasma mass spectroscopy. Results: The Kruskal-Wallis test showed that there was no significant difference in colony counts among the coated wires during 1-4 weeks (p<0.48). In the uncoated-wire groups, colonys count at week 1 were higher than weeks 24 -(p<0.022). Wilcoxon's test showed that the number of colonies was significantly different in groups A and C, but there was no significant difference in groups B or D. MTT-assay results showed that there was not a significant difference between cell viability in the coated-wire group and the control. The Kruskal-Wallis test showed that there was no significant difference in titanium concentration in the studied groups (p<0.834). Conclusion: Application of titanium dioxide coating is effective in reducing bacterial adhesion at wire insertion.

orthodontic wire

Streptococcus mutans

bacterial adhesion

titanium dioxide

Author

Vahid Mollabashi

Hamedan University of Medical Sciences

Abbas Farmany

Hamedan University of Medical Sciences

Mohammad Yousef Alikhani

Hamedan University of Medical Sciences

Mohammad Sattari

Chalmers, Physics, Microstructure Physics

Ali Reza Soltanian

Hamedan University of Medical Sciences

Parnian Kahvand

Hamedan University of Medical Sciences

Ziba Banisafar

Hamedan University of Medical Sciences

International journal of nanomedicine

1176-9114 (ISSN) 1178-2013 (eISSN)

Vol. 15 8759-8766

Subject Categories

Manufacturing, Surface and Joining Technology

Dentistry

Biomaterials Science

DOI

10.2147/IJN.S258440

PubMed

33204086

More information

Latest update

12/7/2020