Heat loss due to thermal bridges in a foundation with floor heating
Paper in proceeding, 2007

This paper provides an overview of the heat losses through the thermal bridge in the junction between a wall and a slab on grade at the perimeter of the foundation. First, the paper discusses the heat losses through the thermal bridge. In particular, the additional heat loss through the thermal bridge due to floor heating. In addition, the paper provides a thorough description of the total heat loss through the thermal bridge in the junction slab on grade and the wall. The result may be used in order to calculate the heat loss through the building envelope of a building.

Author

Peter Roots

Swedish District Heating Association

Carl-Eric Hagentoft

Chalmers, Civil and Environmental Engineering, Building Technology

Thermal Performance of the Exterior Envelopes of Whole Buildings

21668469 (eISSN)


9781933742281 (ISBN)

10th International Conference on Thermal Performance of Exterior Envelopes of Whole Buildings 2007
Clearwater, USA,

Subject Categories

Energy Engineering

Other Civil Engineering

Building Technologies

More information

Latest update