Oscilloscope based two-port measurement system using error-corrected modulated signals
Paper in proceeding, 2012

A technique to accurately measure modulated wideband signals in a two-port context is presented. The technique uses a four channel high frequency digital sampling oscilloscope to perform in-situ correction of both amplitude and phase of the modulated stimulus signal. An advantage of the proposed technique is that no assumption about the group delay has to be made. The technique is demonstrated in a source-pull system. The results clearly demonstrate the necessity of using error-correction in tuner based setups due to the large variations in group-delay over the measurement bandwidth. © 2012 IEEE.

Author

Kristoffer Andersson

Chalmers, Microtechnology and Nanoscience (MC2), Microwave Electronics

Christian Fager

Chalmers, Microtechnology and Nanoscience (MC2), Microwave Electronics

2012 Workshop on Integrated Nonlinear Microwave and Millimetre-Wave Circuits, INMMIC 2012

6331932
978-146732949-1 (ISBN)

Subject Categories

Electrical Engineering, Electronic Engineering, Information Engineering

DOI

10.1109/INMMIC.2012.6331932

ISBN

978-146732949-1

More information

Latest update

4/20/2022