Use of advanced composite curves for assessing cost-effective HEN retrofit I: Theory and concepts
Artikel i vetenskaplig tidskrift, 2009

This paper presents the theory and concepts of a graphical method for heat exchanger network (HEN) retrofit that gives new insights about the complexity and possible solutions of different retrofit alternatives. The method uses knowledge about the placement of heaters/coolers in the existing HEN to evaluate the potential for cost-effective retrofit. One general result this method predicts is that the closer to the pinch the existing heaters/coolers are located, the higher the potential for cost-effective retrofit. Networks that are badly engineered from a grass-root perspective, prove to be a good basis for cost-effective retrofits.

Composite curves

Retrofit

Pinch technology

Heat exchanger network

Författare

Roger Nordman

Industriella energisystem och tekniker

Thore Berntsson

Industriella energisystem och tekniker

Applied Thermal Engineering

1359-4311 (ISSN)

Vol. 29 2-3 275-281

Ämneskategorier

Kemiteknik

DOI

10.1016/j.applthermaleng.2008.02.021

Mer information

Skapat

2017-10-06