Measurements of intense beams of Li-11 from a tantalum foil target
Artikel i vetenskaplig tidskrift, 1999

The yields of Li-11 from a tantalum target, constructed from very thin foils, have been measured at ISOLDE and found to be an order of magnitude greater than those previously measured for a standard roll foil target. The modifications to the existing target designs were based on theoretical modelling calculations. The tantalum foils are 2 mu m thick and the target mass is only one tenth of normal foil targets. (C) 1999 Elsevier Science B.V. All rights reserved.