Adrenal lesions: variability in attenuation over time, between scanners, and between observers.
Artikel i vetenskaplig tidskrift, 2013

BackgroundMeasurements of attenuation (in Hounsfield units [HU]) and contrast wash-out are widely used to characterize adrenal lesions as benign or indeterminate/malignant at computed tomography (CT). Clinical experience suggests that such measurements of adrenal lesions may vary over time and between observers, making evaluation difficult.PurposeTo investigate the change over time of adrenal lesion size, attenuation, and contrast wash-out at CT, to determine inter-observer variability, and to analyze other factors underlying the variability.Material and MethodsIn a cohort of patients, with or without malignant disease, undergoing CT, adrenal lesions were prospectively analyzed. Lesions with growth >20% or >5 mm over 6 months were excluded. Non-enhanced attenuation and contrast medium wash-out over 2-year follow-up were analyzed. An inter-observer analysis with five observers and a phantom study of eight different CT scanners were performed to assess measurement variability.ResultsMean adrenal lesion non-enhanced attenuation values decreased by 0.5 HU/year during follow-up. Using 10 HU or 40% relative wash-out as threshold values for benign versus indeterminate lesions, 27 (20%) and 39 (29%) of 136 lesions, respectively, would be reclassified at some occasion during follow-up. In the observer analysis 37 of 40 lesions demonstrated agreement between all observers, using established threshold values. The phantom study showed an intra-scanner variability of 1-3 HU, but an inter-scanner variability of up to 8 HU for water.ConclusionThe clinically widespread use of specific attenuation threshold values for characterizing adrenal lesions must be used with great caution, considering that multiple factors, related to patient, equipment, scanning technique, and observer influence the outcome.

computed tomography

observer variation

adrenal gland neoplasm

phantoms

Adrenal incidentaloma

Författare

Lilian Hammarstedt

Göteborgs universitet

Anne Thilander-Klang

Göteborgs universitet

Andreas Muth

Göteborgs universitet

Bo Wängberg

Göteborgs universitet

Anders Odén

Chalmers, Matematiska vetenskaper, Matematisk statistik

Göteborgs universitet

Mikael Hellström

Göteborgs universitet

Acta Radiologica

0284-1851 (ISSN) 1600-0455 (eISSN)

Vol. 54 7 817-826

Ämneskategorier

Kardiologi

Radiologi och bildbehandling

DOI

10.1177/0284185113482688

PubMed

23562860

Mer information

Skapat

2017-10-07