Valid and efficient manual estimates of intracranial volume from magnetic resonance images
Artikel i vetenskaplig tidskrift, 2015

Background: Manual segmentations of the whole intracranial vault in high-resolution magnetic resonance images are often regarded as very time-consuming. Therefore it is common to only segment a few linearly spaced intracranial areas to estimate the whole volume. The purpose of the present study was to evaluate how the validity of intracranial volume estimates is affected by the chosen interpolation method, orientation of the intracranial areas and the linear spacing between them. Methods: Intracranial volumes were manually segmented on 62 participants from the Gothenburg MCI study using 1.5 T, T-1-weighted magnetic resonance images. Estimates of the intracranial volumes were then derived using subsamples of linearly spaced coronal, sagittal or transversal intracranial areas from the same volumes. The subsamples of intracranial areas were interpolated into volume estimates by three different interpolation methods. The linear spacing between the intracranial areas ranged from 2 to 50 mm and the validity of the estimates was determined by comparison with the entire intracranial volumes. Results: A progressive decrease in intra-class correlation and an increase in percentage error could be seen with increased linear spacing between intracranial areas. With small linear spacing (<= 15 mm), orientation of the intracranial areas and interpolation method had negligible effects on the validity. With larger linear spacing, the best validity was achieved using cubic spline interpolation with either coronal or sagittal intracranial areas. Even at a linear spacing of 50 mm, cubic spline interpolation on either coronal or sagittal intracranial areas had a mean absolute agreement intra-class correlation with the entire intracranial volumes above 0.97. Conclusion: Cubic spline interpolation in combination with linearly spaced sagittal or coronal intracranial areas overall resulted in the most valid and robust estimates of intracranial volume. Using this method, valid ICV estimates could be obtained in less than five minutes per patient.

Magnetic resonance imaging

Intracranial volume

Manual estimation

Validity

Författare

Niklas Klasson

Göteborgs universitet

Erik Olsson

Göteborgs universitet

Mats Rudemo

Chalmers, Matematiska vetenskaper, Matematisk statistik

Göteborgs universitet

Carl Eckerström

Göteborgs universitet

Helge Malmgren

Göteborgs universitet

Anders Wallin

Göteborgs universitet

BMC Medical Imaging

14712342 (eISSN)

Vol. 15 1 Art. no. 5- 5

Ämneskategorier

Radiologi och bildbehandling

DOI

10.1186/s12880-015-0045-4

Mer information

Skapat

2017-10-08