FTIR Analysis of Nitrogen Species in a Fluidized Bed Combustion Chamber
Övrigt konferensbidrag, 1994

The present paper shows how the FTIR measurements in the combustion chamber of a commercial fluidized bed boiler was performed and evaluated. Problems with interfering compounds are discussed. It is concluded that the present instrument is not suitable for measurement of hydrogen cyanide. The influence of instrument resolution and the removal of the main interfering component, carbon dioxide are demonstrated. However, the problem with interfering species is much less severe for ammonia, and the present instrument can be used for the determination of this species.

fluidized bed combustion

interference

FTIR analysis

CO2

ammonia

HCN

NH3

hydrogen cyanide

Författare

Lars-Erik Åmand

Institutionen för energiomvandling

Claes Tullin

Proceedings of the Nordic Seminar on Gas Analysis in Combustion held October 4-5, 1994 in Tampere, Finland

Drivkrafter

Hållbar utveckling

Ämneskategorier

Energiteknik

Annan naturresursteknik

Styrkeområden

Energi

Infrastruktur

Chalmers kraftcentral

Mer information

Skapat

2017-10-07