Evaluation of 5 years’ performance of VIPs in a retrofitted building façade
Artikel i vetenskaplig tidskrift, 2016

The challenges to retrofit buildings urges for technologies and novel building materials to be developed. In many cases the space for additional insulation in the building envelope is limited. Vacuum insulation panels (VIPs) have a significantly lower thermal conductivity than conventional insulation materials which means less thickness is required to achieve the targeted thermal transmittance. VIPs have been used in buildings since the late 1990s and there exists experience from using them in numerous applications. Besides the higher initial cost for using VIPs in buildings there is still hesitation among architects and engineers whether this component will withstand long-term use in buildings. Therefore further investigations are needed to evaluate its long-term performance. This paper presents experiences from a case study of a previously non-insulated wall insulated with VIPs. Measurements of the temperature and relative humidity in the wall during 5 years show no sign of deterioration of the VIPs and there is a low risk for condensation in the construction. The measurements are continuous with the aim to determine the long-term performance of VIPs in building applications.

listed building

vacuum insulation panel

measurement

case study

Retrofitting

Författare

[Person 4444b6fe-24a3-4b83-9ed7-3487d94c0f6f not found]

[Person 77dc0294-1915-46b8-91fd-231b5c733fd5 not found]

[Person b4b637f5-9413-443e-905f-15e2fd6a33c9 not found]

Energy and Buildings

0378-7788 (ISSN)

Vol. 130 488-494

Drivkrafter

Hållbar utveckling

Styrkeområden

Building Futures (2010-2018)

Energi

Ämneskategorier (SSIF 2011)

Husbyggnad

DOI

10.1016/j.enbuild.2016.08.073

Mer information

Senast uppdaterat

2026-04-07