Progress in the development of the neutron flux monitoring system of the French GEN-IV SFR: Simulations and experimental validations
Paper i proceeding, 2015

The neutron flux monitoring system of the French GEN-IV sodium-cooled fast reactor will rely on high-temperature fission chambers installed in the reactor vessel and capable of operating over a wide-range neutron flux. The definition of such a system is presented and the technological solutions are justified with the use of simulation and experimental results. © 2015 IEEE.

Författare

C. Jammes

Le Commissariat à l’Énergie Atomique et aux Énergies Alternatives (CEA)

P. Filliatre

Le Commissariat à l’Énergie Atomique et aux Énergies Alternatives (CEA)

Zsolt Elter

Chalmers, Teknisk fysik, Nukleär teknik

V. Verma

Uppsala universitet

G. De Izarra

Le Commissariat à l’Énergie Atomique et aux Énergies Alternatives (CEA)

H. Hamrita

Le Commissariat à l’Énergie Atomique et aux Énergies Alternatives (CEA)

M. Bakkali

Le Commissariat à l’Énergie Atomique et aux Énergies Alternatives (CEA)

N. Chapoutier

AREVA NC SA

A. C. Scholer

AREVA NC SA

D. Verrier

AREVA NC SA

C. Hellesen

Uppsala universitet

S. Jacobsson Svärd

Uppsala universitet

B. Cantonnet

PHONIS France S.A.S

J. C. Nappé

PHONIS France S.A.S

P. Molinié

SUPELEC Campus de Gif

P. Dessante

SUPELEC Campus de Gif

R. Hanna

SUPELEC Campus de Gif

M. Kirkpatrick

SUPELEC Campus de Gif

E. Odic

SUPELEC Campus de Gif

F. Jadot

Le Commissariat à l’Énergie Atomique et aux Énergies Alternatives (CEA)

2015 4th International Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications, ANIMMA 2015


978-147999918-7 (ISBN)

Ämneskategorier

Fysik

DOI

10.1109/ANIMMA.2015.7465647

ISBN

978-147999918-7

Mer information

Senast uppdaterat

2018-09-06