New Pinch Technology Based HEN Analysis Methodologies for Cost-Effective Retrofitting
Artikel i vetenskaplig tidskrift, 2001

In this paper, new pinch technology based curves for retrofitting of heat exchangers are presented. Advantages compared to traditional pinch curves, and the information that can be extracted from these curves, are discussed. The curves have been applied to an example where different energy saving levels has been studied. The results have been verified by detailed calculations using the Matrix method.

composite curves

retrofit

cost-effective.

pinch technology

heat exchanger network

Författare

Roger Nordman

Institutionen för värmeteknik och maskinlära

Thore Berntsson

Institutionen för värmeteknik och maskinlära

Canadian Journal of Chemical Engineering

1404-7098 (ISSN)

Vol. 79 4, August 2001 655-662

Ämneskategorier

Kemiteknik

DOI

10.1002/cjce.5450790426

Mer information

Skapat

2017-10-07