Heat transfer in falling film lithiumbromide-water evaporator, an experimental study
Paper i proceeding, 1991

The heat transfer for evaporation of pure water and desorption of water from a LiBr-water solution were measured in a vertical falling film evaporator. The results for water could be well represented by a new correlation. Heat transfer for LiBr-water was significantly lower compared to water. A dependence on heat flux was noticed for LiBr-water.

Författare

Per Holmberg

Institutionen för värmeteknik och maskinlära

Lennart Persson

Institutionen för värmeteknik och maskinlära

Thore Berntsson

Institutionen för värmeteknik och maskinlära

Föredrag vid XIIIth International Congress of Refigeration Montreal, Québec, Canada, 10-17 augusti 1991