Evaluation of an automatic system for detection and positioning of small pore defects using digital radiography
Paper i proceeding, 2013

A recently developed algorithm for positioning of small defects within metal bodies using digital radiography has been experimentally validated. The algorithm has been validated in the high contrast to noise limit. A calibration method has also been developed and validated. The average error in defect interspacings are found to be approximately0.03mm with a maximum at0.2mm, this is at the same order as the errors predicted by simulations. The relative error in interspacings are all less than 2% which is comparable to simulated ideal case at 0.25 %.

Digital Radiography

X-ray Imaging

Non Destructive Testing

Författare

Erik Lindgren

Chalmers, Material- och tillverkningsteknik, Avancerad oförstörande provning

Lars Hammar

Chalmers, Material- och tillverkningsteknik, Avancerad oförstörande provning

AIP Conference Proceedings

0094243X (ISSN) 15517616 (eISSN)

Vol. 32 1511 1646-1653
978-0-7354-1129-6 (ISBN)

Ämneskategorier

Materialteknik

Annan materialteknik

Styrkeområden

Transport

Produktion

Materialvetenskap

DOI

10.1063/1.4789239

Mer information

Senast uppdaterat

2023-10-05