SQUID magnetometer based on Grooved Dayem nanobridges and a flux transformer
Paper i proceeding, 2019

We report noise measurements performed on a SQUID magnetometer implementing Grooved Dayem nanobridge of YBCO as weak-links. The SQUID shows magnetic flux noise as low as 10μΦ 0}/Hz0.5. The magnetometer is realized by coupling the SQUID to a flux transformer with a two-level coupling scheme using a flip-chip approach. This improves the effective area of the SQUID and result in a magnetic field noise of 50fT/Hz0.5atT=77K.

High-Tc

grooved Dayem bridge

SQUID

magnetometer

YBCO

Författare

Edoardo Trabaldo

Chalmers, Mikroteknologi och nanovetenskap, Kvantkomponentfysik

Christoph Pfeiffer

Chalmers, Mikroteknologi och nanovetenskap, Kvantkomponentfysik

Eric Andersson

Chalmers, Mikroteknologi och nanovetenskap, Kvantkomponentfysik

Riccardo Arpaia

Chalmers, Mikroteknologi och nanovetenskap, Kvantkomponentfysik

Alexei Kalaboukhov

Chalmers, Mikroteknologi och nanovetenskap, Kvantkomponentfysik

Dag Winkler

Chalmers, Mikroteknologi och nanovetenskap, Kvantkomponentfysik

Floriana Lombardi

Chalmers, Mikroteknologi och nanovetenskap, Kvantkomponentfysik

Thilo Bauch

Chalmers, Mikroteknologi och nanovetenskap, Kvantkomponentfysik

ISEC 2019 - International Superconductive Electronics Conference

8990909

17th IEEE International Superconductive Electronics Conference, ISEC 2019
Riverside, USA,

Ämneskategorier

Annan fysik

Signalbehandling

Annan elektroteknik och elektronik

DOI

10.1109/ISEC46533.2019.8990909

Mer information

Senast uppdaterat

2020-10-30