Case study of aerobic granular sludge and activated sludge—Energy usage, footprint, and nutrient removal
Artikel i vetenskaplig tidskrift, 2023

This study demonstrates a comparison of energy usage, land footprint, and volumetric requirements of municipal wastewater treatment with aerobic granular sludge (AGS) and conventional activated sludge (CAS) at a full-scale wastewater treatment plant characterized by large fluctuations in nutrient loadings and temperature. The concentration of organic matter in the influent to the AGS was increased by means of hydrolysis and bypassing the pre-settler. Both treatment lines produced effluent concentrations below 5 mg BOD7 L−1, 10 mg TN L−1, and 1 mg TP L−1, by enhanced biological nitrogen- and phosphorus removal. In this case study, the averages of volumetric energy usage over 1 year were 0.22 ± 0.08 and 0.26 ± 0.07 kWh m−3 for the AGS and CAS, respectively. A larger difference was observed for the energy usage per reduced population equivalents (P.E.), which was on average 0.19 ± 0.08 kWh P.E.−1 for the AGS and 0.30 ± 0.08 kWh P.E.−1 for the CAS. However, both processes had the potential for decreased energy usage. Over 1 year, both processes showed similar fluctuations in energy usage, related to variations in loading, temperature, and DO. The AGS had a lower specific area, 0.3 m2 m−3 d−1, compared to 0.6 m2 m−3 d−1 of the CAS, and also a lower specific volume, 1.3 m3 m−3 d−1 compared to 2.0 m3 m−3 d−1. This study confirms that AGS at full-scale can be compact and still have comparable energy usage as CAS. Practitioner Points: Full-scale case study comparison of aerobic granular sludge (AGS) and conventional activated sludge (CAS), operated in parallel. AGS had 50 % lower footprint compared to CAS. Energy usage was lower in the AGS, but both processes had potential to improve the energy usage efficiency. Both processes showed low average effluent concentrations.

activated sludge

land footprint

full-scale wastewater treatment

electricity usage

biological nutrient removal

volume requirement

aerobic granular sludge

Författare

Jennifer Ekholm

Chalmers, Arkitektur och samhällsbyggnadsteknik, Vatten Miljö Teknik

Mark de Blois

H2OLAND AB

Frank Persson

Chalmers, Arkitektur och samhällsbyggnadsteknik, Vatten Miljö Teknik

David Gustavsson

Sweden Water Research

VA SYD

Simon Bengtsson

Sweden Water Research

VA SYD

Tim van Erp

Strömstad Akademi

Britt-Marie Wilen

Chalmers, Arkitektur och samhällsbyggnadsteknik, Vatten Miljö Teknik

Water Environment Research

1061-4303 (ISSN) 15547531 (eISSN)

Vol. 95 8 e10914

Ämneskategorier

Vattenteknik

Vattenbehandling

Miljövetenskap

Annan elektroteknik och elektronik

DOI

10.1002/wer.10914

PubMed

37494966

Mer information

Senast uppdaterat

2023-10-09