Effects, Safety, and Treatment Experience of Advanced Hybrid Closed-Loop Systems in Clinical Practice Among Adults Living With Type 1 Diabetes
Artikel i vetenskaplig tidskrift, 2024

Background: There are few studies providing a more comprehensive picture of advanced hybrid closed-loop (AHCL) systems in clinical practice. The aim was to evaluate the effects of the AHCL systems, Tandem® t: slim X2™ with Control IQ™, and MiniMed™ 780G, on glucose control, safety, treatment satisfaction, and practical barriers for individuals with type 1 diabetes. Method: One hundred forty-two randomly selected adults with type 1 diabetes at six diabetes outpatient clinics in Sweden at any time treated with either the Tandem Control IQ (TCIQ) or the MiniMed 780G system were included. Glycated hemoglobin A1c (HbA1c) and glucose metrics were evaluated. Treatment satisfaction and practical barriers were examined via questionnaires. Results: Mean age was 42 years, median follow-up was 1.7 years, 58 (40.8%) were females, 65% used the TCIQ system. Glycated hemoglobin A1c was reduced by 0.6% (6.8 mmol/mol; 95% confidence interval [CI] = 0.5-0.8% [5.3-8.2 mmol/mol]; P <.001), from 7.3% to 6.7% (57-50 mmol/mol). Time in range (TIR) increased with 14.5% from 57.0% to 71.5% (95% CI = 12.2%-16.9%; P <.001). Time below range (TBR) (<70 mg/dL, <3.9 mmol/L) decreased from 3.8% to 1.6% (P <.001). The standard deviation of glucose values was reduced from 61 to 51 mg/dL (3.4-2.9 mmol/L, P <.001) and the coefficient of variation from 35% to 33% (P <.001). Treatment satisfaction increased, score 14.8 on the Diabetes Treatment Satisfaction Questionnaire (DTSQ) (change version ranging from −18 to 18, P <.001). Four severe hypoglycemia events were detected and no cases of ketoacidosis. Skin problems were experienced by 32.4% of the study population. Conclusions: Advanced hybrid closed-loop systems improve glucose control with a reasonable safety profile and high treatment satisfaction. Skin problems are common adverse events.

patient-reported outcome

advanced hybrid closed loop

time in range

type 1 diabetes

Författare

Ramanjit Singh

Göteborgs universitet

Sahlgrenska universitetssjukhuset

Henrik Imberg

Chalmers, Matematiska vetenskaper, Tillämpad matematik och statistik

Statistiska Konsultgruppen

Göteborgs universitet

Shilan Seyed Ahmadi

Göteborgs universitet

Sahlgrenska universitetssjukhuset

Sara Hallström

Göteborgs universitet

Sahlgrenska universitetssjukhuset

Johan Jendle

Faculty of Medicine and Health

Bengt Olov Tengmark

Citydiabetes

Anna Folino

Sahlgrenska universitetssjukhuset

Ekström Marie

NU-sjukvården

Marcus Lind

NU-sjukvården

Sahlgrenska universitetssjukhuset

Göteborgs universitet

Journal of diabetes science and technology

19322968 (eISSN)

Vol. In Press

Ämneskategorier

Endokrinologi och diabetes

Omvårdnad

DOI

10.1177/19322968241242386

PubMed

38629871

Mer information

Senast uppdaterat

2024-08-19