Regenerating-mode stabilization of the "statically compensated voltage model''
Artikel i vetenskaplig tidskrift, 2007

Reversal of rotation under load of sensorless induction motor drives is very challenging, as there is often an unstable region in the low-speed regenerating mode. In this paper, a variant of the classical "voltage model," i.e., the "statically compensated voltage model," is modified for stable regenerating-mode operation with accurate model motor parameters. The mechanisms behind two low-speed instability phenomena are thereafter, explored, and methods for avoiding instability with inaccurate model parameters are developed. Experimental results verify the theory and show adequate performance.

INDUCTION-MOTOR DRIVES

MACHINES

flux estimation

OBSERVER

VECTOR CONTROL

OPERATION

sensorless control

DESIGN

SPEED

induction motor (IM)

Författare

Lennart Harnefors

Chalmers, Energi och miljö, Elkraftteknik

Rolf Ottersten

Chalmers

GM Powertrain Sweden AB

IEEE Transactions on Industrial Electronics

0278-0046 (ISSN) 15579948 (eISSN)

Vol. 54 2 818-824

Ämneskategorier

Övrig annan teknik

DOI

10.1109/tie.2007.891781

Mer information

Senast uppdaterat

2021-11-12