Many pulp mill hot and warm water systems are overdimensioned and produce more hot and warm water than demanded. This overproduction could be used for other applications, if heat could be released at high enough temperatures. In this paper a new method to release as much excess heat of a high temperature as possible in the secondary heat system has been developed. A case study of a Swedish kraft pulp mill showed that 5-6 MW excess heat with a temperature above 90oC could be released if the system were rebuilt. Two different alternatives for using the excess heat have been investigated.

Pinch analysis

Hot and warm water system

Pulp mill

Heat recovery

Optimization

Författare

Roger Nordman

Industriella energisystem och tekniker

Thore Berntsson

Industriella energisystem och tekniker

Applied Thermal Engineering

1359-4311 (ISSN)

Vol. 26 4 363-373

Ämneskategorier

Energiteknik

DOI

10.1016/j.applthermaleng.2005.06.001