Position-sensorless control of a submersible PMSM fed over a long cable and two transformers
Paper i proceeding, 2014

This paper proposes the combination of two sensorless control algorithms for the secure start-up and the efficient operation of a remotely-controlled PMSM. V / f control is applied during the start-up of the motor and vector control is used for operation at higher speeds. The investigated system consists of a long step-out configuration with a cable and two transformers between the PMSM and its VSD. The system is tested with simulations and with experiments on a lab model. The results demonstrate that V / f control can safely start the PMSM. The effect of the inertia of the rotating assembly, the load torque and the initial rotor position on the start-up performance of the system is investigated and the successful transition from V / f control to vector control is demonstrated.

vector control

sensorless control

Permanent magnet motor

Författare

D. Stellas

FMC Technologies

M.T. Hansen

FMC Technologies

Torbjörn Thiringer

Chalmers, Energi och miljö, Elkraftteknik

T. Stroømsvik

FMC Technologies

H.B. Ulvestad

FMC Technologies

2014 16th European Conference on Power Electronics and Applications (EPE'14-ECCE Europe), Lappeenranta, Finland, 26-28 August 2014

2325-0313 (ISSN)


978-147993015-9 (ISBN)

Ämneskategorier

Elektroteknik och elektronik

DOI

10.1109/EPE.2014.6910696