Surface oxidation behavior of Ti-6Al-4V manufactured by Electron Beam Melting (EBM (R))
Artikel i vetenskaplig tidskrift, 2015

Additive manufacturing is an emerging manufacturing technology that enables production of patient specific implants, today primarily out of titanium. For optimal functionality and proper integration between the titanium implant and the body tissues surface properties, such as surface oxide thickness is of particular importance, as it is primarily the surface of the material which interacts with the body. Hence, in this study the surface oxidation behavior of titanium parts manufactured by Electron Beam Melting (EBM (R)) is investigated using the surface sensitive techniques ToF-SIMS and AES. Oxide thicknesses comparable to those found on conventionally machined surfaces are found by both analysis techniques. However, a build height dependency is discovered for different locations of the EBM (R) manufactured parts due to the presence of trapped moisture in the machine and temperature gradients in the build.

Titanium alloys

Electron Beam Melting (EBM (R))

Oxidation

Surface properties

Additive manufacturing

Författare

J. Karlsson

SP Sveriges Tekniska Forskningsinstitut

Uppsala universitet

Mats Norell

Chalmers, Material- och tillverkningsteknik, Yt- och mikrostrukturteknik

U. Ackelid

H. Engqvist

Uppsala universitet

Jukka Lausmaa

SP Sveriges Tekniska Forskningsinstitut

Journal of Manufacturing Processes

1526-6125 (ISSN)

Vol. 17 120-126

Ämneskategorier

Bearbetnings-, yt- och fogningsteknik

DOI

10.1016/j.jmapro.2014.08.005