Exploration of a transient method for measurements of airtightness
Paper i proceeding, 2006

By measuring the pressure decline in a pressurised air volume from which air is leaking it is possible to determine the air leakage rate as a function of the pressure difference. The leakage rate is proportional to the time derivative of the pressure. The constants of proportionality turns out to depend on the size of the pressurised volume, the ambient pressure, the change in temperature in the bulk volume of the pressurised air and the stiffness of the structure enclosing the pressurised volume. The studies and analyses leading to a final equation relating air leakage to pressure drop is described. It is shown that the very small temperature drop in the bulk air volume has to be accounted for. Initial tests of the method have been performed. The final, quite handy, equation shows good agreement with air leakage rates obtained with theoretical as well as with standard methods.

air leakage

airtightness

pressurisation measurements

blower door

Författare

Björn Mattsson

Chalmers, Bygg- och miljöteknik, Byggnadsteknologi

Johan Claesson

Chalmers, Bygg- och miljöteknik, Byggnadsteknologi

Research in Building Physics and Building Engineering. The Third International Building Physics Conference, Concordia University, Montreal, Canada, 27-31 August 2006


0-415-41675-2 (ISBN)

Ämneskategorier

Annan samhällsbyggnadsteknik

ISBN

0-415-41675-2

Mer information

Skapat

2017-10-07