Mitigation of SSCI in DFIG based wind farms through modification of Rotor-Side Converter Controller
Paper i proceeding, 2017

This paper presents a mitigation strategy to reduce the risk of Subsynchronous Controller Interaction (SSCI) in Doubly-Fed Induction Generator (DFIG) based wind farms. SSCI mitigation is achieved through the modification of the controller structure within the DFIG turbine. A proportional damping controller tuned to the SSCI oscillatory frequency is proposed and implemented in the current controller loop that regulates the rotor current of the DFIG, aiming at enhancing the system damping at the frequency of interest. Time-domain simulations are used to prove the effectiveness of the proposed controller in reducing the risk of SSCI.

Författare

Selam Chernet

Chalmers, Energi och miljö, Elkraftteknik

Massimo Bongiorno

Chalmers, Energi och miljö, Elkraftteknik

3rd IEEE International Future Energy Electronics Conference and ECCE Asia, IFEEC - ECCE Asia 2017; Kaohsiung; Taiwan; 3 June 2017 through 7 June 2017

603-608 7992107
978-1-5090-5158-8 (ISBN)

Styrkeområden

Energi

Ämneskategorier

Annan elektroteknik och elektronik

DOI

10.1109/IFEEC.2017.7992107

ISBN

978-1-5090-5158-8

Mer information

Senast uppdaterat

2018-03-23