New measurement approaches for film thickness and wall temperature in falling film heat exchangers
Paper i proceeding, 2015
food and pulp & paper industry. Evaporation is very energy intense and relatively small efficiency improvements to the techniques can lead to large savings in absolute numbers. Falling film evaporation is affected by the wave dynamics; hence further knowledge of the behaviour of the liquid film flow can promote efficiency improvements. In this work, two new measurement approaches have
been investigated. The first approach is to use a laser triangulation scanner combined with a high-speed camera where the laser scanner continuously measures the film thickness along a vertical line, resolving the flow pattern in high detail. The second approach is to measure local wall temperatures, enabling calculation of local heat transfer coefficients at any desired location. These methods has been tested and evaluated in a falling
film test facility. Both approaches have proven to give valuable insights into the process and the results are in good agreement with literature data.
Författare
Anders Åkesjö
Chalmers, Energi och miljö, Industriella energisystem och tekniker
Lars Olausson
Chalmers, Energi och miljö, Industriella energisystem och tekniker
Lennart Vamling
Chalmers, Energi och miljö, Industriella energisystem och tekniker
Mathias Gourdon
Chalmers, Energi och miljö, Industriella energisystem och tekniker
Proceedings of the 11th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics
Kruger National Park, South Africa, South Africa,
Ämneskategorier
Energiteknik
Annan kemiteknik
Strömningsmekanik och akustik
Styrkeområden
Energi