AMCW Radar of Micrometer Accuracy Distance Measurement and Monitoring
Paper i proceeding, 2019

An Amplitude Modulated Continuous Wave (AMCW) radar system is proposed that uses both the phase from the envelope and carrier to achieve micrometer accuracy distance measurement. The system has the benefit of using only two frequencies instead of an entire frequency band which is the case with FMCW radars. Many radar systems can therefore be used in a small area without risking interference. An experimental radar setup at 78 GHz is measured and verified to have a measurement error magnitude of less than 10 micrometer. This system is suitable for modern manufacturing and industry.

distance measurement

Amplitude modulation

Industry 4.0

AMCW

millimeter-wave

monitoring

radar

Författare

Frida Strömbeck

Chalmers, Mikroteknologi och nanovetenskap, Mikrovågselektronik

Zhongxia Simon He

Chalmers, Mikroteknologi och nanovetenskap, Mikrovågselektronik

Herbert Zirath

Chalmers, Mikroteknologi och nanovetenskap, Mikrovågselektronik

IEEE MTT-S International Microwave Symposium Digest

0149645X (ISSN)

Vol. 2019-June 1473-1475 8701002
978-1-7281-1309-8 (ISBN)

2019 IEEE MTT-S International Microwave Symposium, IMS 2019
Boston, USA,

Ämneskategorier

Övrig annan teknik

Reglerteknik

Signalbehandling

DOI

10.1109/MWSYM.2019.8701002

Mer information

Senast uppdaterat

2023-03-21