Characteristics of partial discharges in an experimental setup reproducing HVDC cable insulation operating conditions
Paper i proceeding, 2021
activity inside an air void defect existing within one of the two dielectric cell is measured by means of a PRY-CAM. This setup reproduces, to the extreme, the effect of the distribution of the electric field in an HVDC cable on PD activity when it is exposed to a thermal gradient across the insulation. In addition, an equivalent circuit model has been developed to evaluate the PD Inception Voltage (PDIV) across the cavity. The comparison between the experimental and model results demonstrates the capability of the macroscopic conduction model to reproduce the inception of PD phenomena in solid dielectrics under HVDC stress and temperature gradient.
partial discharge
electric insulation
hvdc cable
Författare
G. Rizzo
Universita degli Studi di Palermo