Influence of PD characteristics within motor windings exposed to elevated temperatures
Paper i proceeding, 2023

Voltage levels used in AC motor drives is ontinuously increasing and this paper compares the electrical stress appearing in two different motor winding insulation specimens. The aim is to explore the changes in Partial discharge characteristics to evaluate grade 2 motor insulation for different temperature levels and rise times of the applied voltage as well as influence of overshoots. Here it is discussed how much deviation in properties than can be expected for different insulation thicknesses. The paper shows for example that elevated temperature influences the time lag considerably as well as the inception voltage level, which both influence the PD exposure of the insulation system.

measurement techniques

diagnostics

overshoots

pulse width modulation (PWM)

Författare

Thomas Hammarström

Chalmers, Elektroteknik, Elkraftteknik

2023 International Symposium on Electrical Insulating Materials

324-327
978-488686437-6 (ISBN)

2023 International Symposium on Electrical Insulating Materials (ISEMS 2023)
Matsue, Japan,

Drivkrafter

Hållbar utveckling

Styrkeområden

Nanovetenskap och nanoteknik

Transport

Energi

Ämneskategorier

Annan elektroteknik och elektronik

DOI

10.23919/iseim60444.2023.10329024

ISBN

9784886864376

Mer information

Senast uppdaterat

2024-09-23