Robustness in fire
Kapitel i bok, 2022

With the increasing number of complex and tall timber buildings with a significant area of unprotected timber surfaces, questions arise about the robustness of these buildings in extreme fire scenarios. In recent building projects, measures for robustness have been implemented on an ad hoc basis in agreement between the designers and the authorities. This chapter discusses general approaches to achieve structural robustness with regard to fire design and evaluates them to give guidance for robust fire design of timber structures.

collapse

buildings

Tall timber

wood

fire

robustness

Författare

Michael Klippel

Eidgenössische Technische Hochschule Zürich (ETH)

Andrea Frangi

Eidgenössische Technische Hochschule Zürich (ETH)

Robert Jockwer

Chalmers, Arkitektur och samhällsbyggnadsteknik, Konstruktionsteknik

Joachim Schmid

Eidgenössische Technische Hochschule Zürich (ETH)

Konstantinos Voulpiotis

Eidgenössische Technische Hochschule Zürich (ETH)

Colleen Wade

Halliwell Fire Research

Fire Safe Use of Wood in Buildings

393-406
9781003190318 (ISBN)

Ämneskategorier (SSIF 2011)

Arkitekturteknik

Annan samhällsbyggnadsteknik

Husbyggnad

Drivkrafter

Hållbar utveckling

DOI

10.1201/9781003190318-12

Mer information

Senast uppdaterat

2026-02-02