Environmental assessment of a novel generator design in a 15 MW wind turbine
Rapport, 2024
This study uses life cycle assessment to investigate how the generator design influence climate change and resource use impacts of a 15 MW wind turbine. The reference designs of IEA Wind task 37 (Gaertner et al., 2020) for a 15 MW floating wind turbine for offshore installation, and a 15 MW monopile wind turbine for shallower sea installation, are included int the study as two reference options. These are compared to two alternative turbine options, instead using the generator proposed by Hagnesia. For the floating option with the Hagnesia generator design, the model also captures the effect of lowered tower and foundation masses, which are allowed for by the load reduction that follows from the shift of generator.
Resource use is evaluated using an indicator for long-term mineral and metal scarcity. The study draws its system boundary at the point in the life cycle when the turbines are commissioned at sea and ready to generate, but it excludes the operation. In line with recommendations from previous literature, to provide transparency and replicability, all unit process-level data compiled specifically for the study is reported in Appendix A.
The conclusion is that Hagnesia’s generator design is able to reduce the greenhouse gas emissions and resource use of the 15 MW wind turbine significantly in comparison to IEA Wind task 37 reference design. The largest impact reduction potential can be identified for the generator subparts, for which the sum of greenhouse gas emissions is more than one order of magnitude lower compared to the reference design.
Life Cycle Assessment
Wind turbine
Permanent magnet
Generator
Författare
Anders Nordelöf
Chalmers, Teknikens ekonomi och organisation, Environmental Systems Analysis
Prestandaverifiering och modellutveckling av Hagnesias generatorkoncept
Energimyndigheten (51370-1), 2021-01-01 -- 2023-12-31.
Drivkrafter
Hållbar utveckling
Styrkeområden
Energi
Ämneskategorier
Elektroteknik och elektronik
Report / Division of Environmental Systems Analysis, Chalmers University of Technology: E2024:004
Utgivare
Chalmers