Variable speed AC-generators applied in WECS
Paper i proceeding, 1986
This paper describes two variable speed ac-drives, the synchronous generator with frequency convertor for large speed range and the rotor cascade induction generator for small variations of speed. Results obtained with transient state calculations using computer models and verifying laboratory tests were performed for the electrical systems. In the synchronous generator system, a frequency convertor with a dc-link is installed between the grid and the generator. The rotor cascade induction generator system, the generator is a standard wound rotor induction machine which rotor circuit is connected to a 6-pulse rectifier. The rectified slip-power can be recovered by feeding it back to the grid via an inverter and a transformer.
A 40 kW, three-bladed, variable pitch wind turbine is used as the test machine at Chalmers Test Station for Windmills. The system with synchronous generator and frequency convertor together with a digital control system has been tested on the windmill.
Wind turbine, variable speed generators, torque control
Författare
Ola Carlson
Elnät och komponenter
Jonny Hylander
Student vid Chalmers
Spiros Tsiolis
Student vid Chalmers
European Wind and Energy Association Conference and Exibition
Vol. 1 685-690 D23
Rome, Italy,
Ämneskategorier (SSIF 2025)
Annan elektroteknik och elektronik
Energiteknik
Naturresursteknik
Styrkeområden
Energi