Deterioration of insulated rail joints – a three-year field study
Paper i proceeding, 2012

Four operational joints at the Swedish West Coast Line have been monitored in field from installation and during three years of operation to follow degradation. Even though operational loads were comparatively low, material damage was found to occur early after installation. All joints showed a similar damage pattern with dominating deformation on the side towards a nearby station. In addition some joints showed “cavity-like” damage on the off-station side. The paper reports observations on continuing degradation of the joints as well as hardness evolution and increased joint dip over time.

Författare

Johan Sandström

Chalmers, Tillämpad mekanik, Material- och beräkningsmekanik

Elena Kabo

Chalmers, Tillämpad mekanik, Material- och beräkningsmekanik

Arne Nissen

Fredrik Jansson

Anders Ekberg

Dynamik

Roger Lundén

Dynamik

Proceedings of the 9th International Conference on Contact Mechanics and Wear of Rail/Wheel Systems (CM2012)

301-308

Drivkrafter

Hållbar utveckling

Styrkeområden

Transport

Building Futures (2010-2018)

Materialvetenskap

Ämneskategorier

Teknisk mekanik

Infrastrukturteknik

Mer information

Skapat

2017-10-07