The extremely low thermal conductivity of vacuum insulation panels (VIP) leads to less required insulation thickness in different applications. This paper aims to present our research findings related to the long-term performance of VIPs based on measurements during the last five years. The measurements were performed both in laboratory and in field where the real condition are present. The performance of an exterior wall retrofitted with VIPs and a hybrid insulated district heating pipe were observed. The expected service life of both application are more than 50 years. Thus, the long-term performance of the VIPs is of interest. The results of the evaluation indicate that there is no considerable performance degradation after five years in the wall application and after three years in the hybrid insulated pipes. The results are promising. However, it is still too soon to make final conclusions of the entire service life performance of the applications.

retrofitting

numerical model

Field study

district heating

laboratory study

Författare

Pär Johansson

Chalmers, Bygg- och miljöteknik, Byggnadsteknologi

Bijan Adl-Zarrabi

Chalmers, Bygg- och miljöteknik, Byggnadsteknologi

Axel Berge

Chalmers, Bygg- och miljöteknik, Byggnadsteknologi

Proceedings of the 12th International Vacuum Insulation Symposium, September 19-20, 2015, Nanjing, China

136-139