Measurements and Modelling of Low-frequency Disturbances in Induction Machines
Licentiatavhandling, 1993

in this thesis the low-frequency dynamic behavior of the induction machine is analyzed. disturbances in the shaft torque and supply voltage are investigated theoretically, The calculated response to shaft torque disturbances is verified with measurements on a 15 kW machine. Furthermore, the influence of the machine parameters, skin effect and operating point is studied. The results predicted using some models of lower orders are compared with measurements and results obtained by using a two-axis model. The results indicate that a first-order model can be used to determine the dynamic response to shaft torque and voltage disturbances up to one or a few hertz. By using a second-order model also higher frequency disturbances could be treated with a rather small loss of accuracy. The temperature significantly effects the low-frequency dynamics of the induction machine while the influence of skin effect and static shaft torque is of less importance to an ordinary industrial machine.

Modelling

induction machine

measurements

Författare

Torbjörn Thiringer

Chalmers, Energi och miljö, Elkraftteknik

Styrkeområden

Energi

Ämneskategorier

Reglerteknik

Matematisk analys

Annan elektroteknik och elektronik

Utgivare

Chalmers

Mer information

Senast uppdaterat

2024-01-28