CARBONATION IN CEMENTITIOUS MATERIALS: CRACKS IN MESOPORES
Övrigt konferensbidrag, 2024
In this study, a multi-faceted approach was employed, utilizing pH indicators, micro-hardness testing, and electrical conductivity measurements on cement mortar samples subjected to accelerated carbonation. After one month of CO2 exposure, the pH indicator gave a carbonation depth of 6 mm. The microhardness data showed an increase in hardness in the carbonated zone meaning that carbonation causes densification of microstructure. Coupled with that, electrical conductivity measurements aligned with pH indicator results. The study concludes that electrical conductivity and microhardness can be employed to investigate carbonation in cementitious systems.
Micro cracks
Electrical conductivity
Microhardness
Carbonation
Författare
Sahar Iftikhar
Byggnadsteknologi 1
Arezou Baba Ahmadi
Chalmers, Arkitektur och samhällsbyggnadsteknik, Byggnadsteknologi
Jelke Dijkstra
Geologi och geoteknik
Luping Tang
Chalmers, Arkitektur och samhällsbyggnadsteknik, Byggnadsteknologi
Ingemar Löfgren
Chalmers, Arkitektur och samhällsbyggnadsteknik, Konstruktionsteknik
Toulouse, France,
Ämneskategorier (SSIF 2025)
Byggnadsmaterial