Predicting occupant head displacements in evasive maneuvers; tuning and comparison of a rotational based and a translational based neck muscle controller
Artikel i vetenskaplig tidskrift, 2023
Methods: The rotational controller was developed using an axis-angle representation of head rotations, with x, y, and z components in the axis. Muscle load sharing was based on rotational direction in the simulation and muscle activity recorded in three volunteer experiments in these directions. The gains of the rotational and translational controller were tuned to minimize differences between translational and rotational head displacements of the HBM and volunteers in braking and lane change maneuvers using multi-objective optimizations. Bio-fidelity of the model with tuned controllers was evaluated objectively using CORrelation and Analysis (CORA).
Results: The results indicated comparable performance for both controllers after tuning, with somewhat higher bio-fidelity for rotational kinematics with the translational controller. After tuning, good or excellent bio-fidelity was indicated for both controllers in the loading direction (forward in braking, and lateral in lane change), with CORA scores of 0.86−0.99 and 0.93−0.98 for the rotational and translational controllers, respectively. For rotational displacements, and translational displacements in the other directions, bio-fidelity ranged from poor to excellent, with slightly higher average CORA scores for the HBM with the translational controller in both braking and lane changing. Time-averaged muscle activity was within one standard deviation of time-averaged muscle activity from volunteers.
Conclusion: Overall, the results show that when tuned, both the translational and rotational controllers can be used to predict the occupant response to an evasive maneuver, allowing for the inclusion of evasive maneuvers prior to a crash in evaluation of vehicle safety. The rotational controller shows potential in controlling omni-directional head displacements, but the translational controller outperformed the rotational controller. Thus, for now, the recommendation is to use the translational controller with tuned gains.
controller tuning
active human body model
SAFER HBM
pre-crash
omni-directional control
Författare
Emma Larsson
Chalmers, Mekanik och maritima vetenskaper, Fordonssäkerhet
Johan Iraeus
Chalmers, Mekanik och maritima vetenskaper, Fordonssäkerhet
Bengt Pipkorn
Autoliv AB
Chalmers, Mekanik och maritima vetenskaper, Fordonssäkerhet
Jan Östh
Volvo
Chalmers, Mekanik och maritima vetenskaper, Strömningslära
Patrick A. Forbes
Erasmus Universiteit Rotterdam
Johan Davidsson
Chalmers, Mekanik och maritima vetenskaper, Fordonssäkerhet
Frontiers in Bioengineering and Biotechnology
2296-4185 (eISSN)
Vol. 11 1313543Ämneskategorier
Farkostteknik
Reglerteknik
DOI
10.3389/fbioe.2023.1313543
PubMed
38283169